MacDon M200 Návod k obsluze Strana 182

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 234
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 181
MAINTENANCE AND SERVICING
Form 169017 / 169087 / 169095 180 Revision C
7.11.1.3 Charging
CAUTION
Ventilate the area where batteries are
being charged.
Do not charge a frozen battery. Warm to
60°F (16°C) before charging.
Do not connect or disconnect live circuits.
To prevent sparks, turn off charger and
connect positive cable first. If charging
battery in windrower, disconnect positive
battery cable before connecting charger
cable, then connect ground cable last,
away from battery.
Stop or cut back charging rate if battery
feels hot, or is venting electrolyte. Battery
temperature must not exceed 125°F (52°C).
Follow all instructions and precautions
furnished by the battery charger
manufacturer. Charge at recommended
rates and times.
7.11.1.4 Boosting
A twelve volt battery can be connected in parallel
(+ to +) with the windrower battery. Use heavy
duty battery cables.
CAUTION
Gas given off by batteries is explosive.
Keep sparks and flames away from
batteries.
Make last connection and first
disconnection at a point furthest away
from the batteries.
Wear protective eye-wear when using a
booster battery.
Be sure everyone is clear of machine when
starting engine. Start engine from
Operator’s station only.
a. Move platform on right cab-forward side of
machine to open position to allow access to the
battery.
b. Remove red rubber cover (A) from windrower
battery positive terminal.
(continued next page)
A
Zobrazit stránku 181
1 2 ... 177 178 179 180 181 182 183 184 185 186 187 ... 233 234

Komentáře k této Příručce

Žádné komentáře